Displays the configuration for the specified profile.
profile_name | Displays configuration and usage information for the specified profile, which can be either a standard or a fast-reroute profile. |
detail | Displays the profile information in verbose format, and displays all LSPs that are configured to use the specified profile. |
N/A.
If the profile_name argument is omitted, the profile parameter values for all profiles are displayed.
The following command displays configuration information for all defined profiles:
# show mpls rsvp-te profile Profile Name Peak Committed Max Burst SPri HPri RRO MTU #LSP ----------------- ---------- ---------- --------- ---- ---- --- ---- ---- default 0 0 0 7 0 Off i/f 0 prof598 0 0 0 7 0 On 1500 1 FRR Profile Name Mode Bandwidth SPri HPri HopLmt P-BW P-Node #LSP ---------------- ------ --------- ---- ---- ------ ---- ------ ---- Prf1_frr Detour 0 7 0 3 Ena Ena 2
The following command displays configuration information for a specific fast-reroute profile:
# show mpls rsvp-te profile prf1_frr detail Profile Name : prf1_frr Profile type : Fast Reroute / Standard Peak Rate : 0 Kbps Committed Rate : 0 Kbps Max Burst Size : 0 Kb Setup Priority : 7 Hold Priority : 4 Hop Limit : 1 Protected BW : Disabled Protect Node : Enabled #LSP References : 2 LSP / Path : pc10_lsp / p1
This command was first available in ExtremeXOS 11.6.
The fast-reroute feature was first available in ExtremeXOS 12.1.
This command is available only on the platforms that support MPLS as described in the Switch Engine v33.1.1 Licensing Guide document.